EVT 200 Frame

The EVT combines the compactness and performance of the VRT series with a right-angle bevel system to provide the ultimate space saving solution for highly dynamic applications. The ISO flange interface allows for easy mounting of index tables, pinions, timing belt pulleys and other mechanical components without the need for a coupling.

Downloads

Technical Data

EVT 200 Frame Size, 2 Stage Specifications

RatioUnitsNote45710
Nominal Output Torque[Nm]*1604646646478
Maximum Acceleration Torque[Nm]*290411271315931
Maximum Torque[Nm]*31064132714981144
Emergency Stop Torque[Nm]*41700200025002000
Nominal Input Speed[rpm]*51500150015001500v
Maximum Input Speed[rpm]*64000400040004000
No Load Running Torque[Nm]*710.810.810.810.8
Maximum Radial Load[N]*840000400004000040000
Maximum Axial Load[N]*930000300003000030000
Maximum Tilting Moment[Nm]*105300530053005300
Moment of Inertia (≤ Ø 28)[kgcm2]
Moment of Inertia (≤ Ø 38)[kgcm2]93.4481.8671.4766.72
Moment of Inertia (≤ Ø 48)[kgcm2]138.1123.3109.6103.4
Moment of Inertia (≤ Ø 65)[kgcm2]223.7208.9195.2189.0
Efficiency[%]*1193939393
Torsional Rigidity[Nm/arc-min]*12320320320320
Maximum Torsional Backlash[arc-min]≤ 6≤ 6≤ 6≤ 6
Noise LeveldB [A]*13≤ 85≤ 85≤ 85≤ 85
Protection Class*14IP54 (IP65)IP54 (IP65)IP54 (IP65)IP54 (IP65)
Ambient Temperature[°C]0-400-400-400-40
Permitted Housing Temperature[°C]90909090
Weight[kg]*1550505050

EVT 200 Frame Size, 3 Stage Specifications

RatioUnitsNotes16202530
Nominal Output Torque[Nm]*1583646683710
Maximum Acceleration Torque[Nm]*21315131513151315
Maximum Torque[Nm]*31315131513151315
Emergency Stop Torque[Nm]*42500250025002500
Nominal Input Speed[rpm]*52100210021002100
Maximum Input Speed[rpm]*64000400040004000
No Load Running Torque[Nm]*74.74.74.74.7
Maximum Radial Load[N]*840000400004000040000
Maximum Axial Load[N]*930000300003000030000
Maximum Tilting Moment[Nm]*105300530053005300
Moment of Inertia (≤ Ø 28)[kgcm2]13.4211.9211.3811.82
Moment of Inertia (≤ Ø 38)[kgcm2]22.2020.7120.1720.61
Moment of Inertia (≤ Ø 48)[kgcm2]27.0225.5324.9925.43
Moment of Inertia (≤ Ø 65)[kgcm2]
Efficiency[%]*1188888888
Torsional Rigidity[Nm/arc-min]*12320320320320
Maximum Torsional Backlash[arc-min]≤ 9≤ 9≤ 9≤ 9
Noise LeveldB [A]*13≤ 85≤ 85≤ 85≤ 85
Protection Class*14IP54 (IP65)IP54 (IP65)IP54 (IP65)IP54 (IP65)
Ambient Temperature[°C]0-400-400-400-40
Permitted Housing Temperature[°C]90909090
Weight[kg]*1537373737
RatioUnitsNote35405070100
Nominal Output Torque[Nm]*1710465710710480
Maximum Acceleration Torque[Nm]*21315131513151315931
Maximum Torque[Nm]*31315131513151315931
Emergency Stop Torque[Nm]*425002500250025002000
Nominal Input Speed[rpm]*521002100210021002100
Maximum Input Speed[rpm]*640004000400040004000
No Load Running Torque[Nm]*74.74.74.74.74.7
Maximum Radial Load[N]*84000040000400004000040000
Maximum Axial Load[N]*93000030000300003000030000
Maximum Tilting Moment[Nm]*1053005300530053005300
Moment of Inertia (≤ Ø 28)[kgcm2]10.910.510.310.210.2
Moment of Inertia (≤ Ø 38)[kgcm2]19.6919.2619.1319.0118.94
Moment of Inertia (≤ Ø 48)[kgcm2]24.5124.0823.9523.8323.77
Moment of Inertia (≤ Ø 65)[kgcm2]
Efficiency[%]*118888888888
Torsional Rigidity[Nm/arc-min]*12320320320320320
Maximum Torsional Backlash[arc-min]≤ 9≤ 9≤ 9≤ 9≤ 9
Noise LeveldB [A]*13≤ 85≤ 85≤ 85≤ 85≤ 85
Protection Class*14IP54 (IP65)IP54 (IP65)IP54 (IP65)IP54 (IP65)IP54 (IP65)
Ambient Temperature[°C]0-400-400-400-400-40
Permitted Housing Temperature[°C]9090909090
Weight[kg]*153737373737
  1. At nominal input speed, service life is 20,000 hours
  2. The maximum torque when starting or stopping operation. Apply Cycle Factor f0, found on page Selection Flow Chart, for higher duty cycle applications
  3. Permitted 10,000 times during service life. Based on 10% of maximum radial load and smooth output shaft
  4. The maximum torque allowed under a stress situation. Permitted 1,000 times during service life
  5. The average input speed at nominal input torque. Maintain housing temperature below permitted value
  6. The maximum intermittent input speed
  7. Torque at no load applied to the input shaft at nominal input speed
  8. The maximum radial load that the gearbox can accept
  9. The maximum axial load that the gearbox can accept
  10. The maximum load at output flange surface
  11. The efficiency at the nominal output torque rating
  12. This does not include lost motion
  13. Contact Nidec Drive Technology for the testing conditions and environment
  14. IP65 (wash-down) is available as an option. Contact Nidec Drive Technology for more details